RJ45/DB9 adapters

Below are diagrams for RJ45 to DB9 adapters allowing connection between an Etherlite serial bay and XINU backends in a pool. The first diagram is for UART 0 (DTE). The second diagram is for the platform-dependent UART 1 (DCE).

UART 0, DTE


UART 1, DCE


Null Modem

The null modem adapter is required to make connections between available UART 1 ports on two machines. The above UART 1 diagram functions as a null modem when connecting directly to other backends, as well as to the EtherLite serial bay.

EtherLite to Baytech

The third diagram represents a connection between the between a Baytech serial-controlled power strip and the EtherLite terminal annex. The final two diagrams are the Baytech/Etherlite diagram broken into two parts, representing the mating of two individual RJ45/DB9 adapters.

Wiring diagram for Baytech to Etherlite connection


same as UART 0 diagram above


Baytech RJ45 to DB9F